DEVELOPMENT AND VALIDATION OF A LEAK DETECTION METHOD IN PIPES WITH A LEAK USING PRESSURE TRANSIENT DATA ASSIMILATION
-
- ASADA Yohei
- 筑波大学 生命環境系
-
- OOYAMA Shuzo
- 東京大学 大学院工学系研究科
-
- SHIN Moono
- 福島大学 農学群食農学類
-
- SUZUKI Tetsuya
- 新潟大学 農学部農学科
Bibliographic Information
- Other Title
-
- 圧力変動データ同化を利用した漏水1点に対応した管内漏水検知法の開発及び検証
Abstract
<p> In this study, a novel leak detection method for pipeline using pressure transient data assimilation with a numerical simulation incorporating a numerical scheme corresponding to a single leak point was developed. The accuracy of estimating the leak location and leakage volume for a single leak point was verified using this method. As a result, in both model pipeline experiments and field pipeline experiments, the estimated leak location error relative to the total length of the pipe was approximately less than 2%, and the leak volume error relative to the measured value was approximately less than 30%, indicating that this leak detection method has a practically feasible level of performance. Furthermore, the limitation of leak detection in terms of leak scale was determined to be approximately 1.70×10-5 and 2.73×10-3 times the pipe cross-sectional area in the model and field pipeline experiments, respectively, which corresponds to be significantly smaller than those reported in previous research, and at a similar level to them.</p>
Journal
-
- Japanese Journal of JSCE
-
Japanese Journal of JSCE 80 (16), n/a-, 2024
Japan Society of Civil Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390017843874946048
-
- ISSN
- 24366021
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
-
- Abstract License Flag
- Disallowed