変位制御材と永久磁石を用いた基礎絶縁建物模型の振動台実験と解析

書誌事項

タイトル別名
  • SHAKING TABLE TEST AND ANALYSIS ON BASE-INSULATED BUILDING MODEL USING DISPLACEMENT CONTROL MATERIAL AND PERMANENT MAGNET

抄録

<p>Authors suggest a base-insulation system using a permanent magnet and a displacement control material made of a compound geomaterial for reducing seismic response of small buildings. The electromagnetic theory provided a method for calculating magnetic force and revealed its important properties such as nonlinearity and negative stiffness. A shaking table test and a finite element analysis demonstrated the response reduction by the magnetically levitated foundation. The analytical study clarified that the restoring force of the displacement control material canceled the magnetic negative stiffness and governed the impedance of the foundation for the seismic response.</p>

収録刊行物

参考文献 (5)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ