The contamination level of stethoscopes in emergency and critical care center ward: Is your stethoscope  really clean?

  • ONOUCHI Shiomi
    Fukushima Medical University, School of Medicine
  • OYAMA Sumihiro
    Fukushima Medical University, School of Medicine
  • YASUNAGA Amane
    Fukushima Medical University, School of Medicine
  • HOSHINO Nagisa
    Fukushima Medical University, School of Medicine
  • OHASHI Kazutaka
    Department of Clinical Laboratory Medicine, Fukushima Medical University Hospital
  • SUZUKI Mitsuko
    Department of Emergency and Critical Care Medicine, Fukushima Medical University, School of Medicine
  • OYAMA Asami
    Department of Emergency and Critical Care Medicine, Fukushima Medical University, School of Medicine
  • ONODERA Makoto
    Department of Regional Emergency Medicine, Fukushima Medical University
  • ISEKI Ken
    Department of Emergency and Critical Care Medicine, Fukushima Medical University, School of Medicine Department of Regional Emergency Medicine, Fukushima Medical University

Bibliographic Information

Other Title
  • 救命救急センター病棟の聴診器の汚染度
  • 救命救急センター病棟の聴診器の汚染度 : その聴診器本当にきれい?
  • キュウメイ キュウキュウ センター ビョウトウ ノ チョウシンキ ノ オセンド : ソノ チョウシンキ ホントウ ニ キレイ?
  • ―その聴診器本当にきれい?―

Search this article

Abstract

<p>目的:聴診器の汚染度を,ルミテスターを用いてATP拭き取り法で測定した。聴診器の汚染度を測定し,その後酒精綿で拭って効果があるかを検討した。方法:救命救急センター病棟で用いている看護師の聴診器を無作為に抽出し,ルミテスターを用いて聴診器の膜型面の汚染度を調べた。酒精綿を用いて10秒間拭き,5分乾かした後に測定した。また,膜型面の細菌培養検査を行った。結果:54個の聴診器について調査を行った。拭き取り前の汚染度は1,895.5 RLU であり,拭き取り後379.5 RLU であった。拭き取り後は前に比べて有意に減少していた。細菌培養検査では常在菌を検出した。考察:病棟で使用されている聴診器は細菌による汚染があった。酒精綿で10秒間拭き取ることにより84%の減少効果があったが,完全には除菌されてはいなかった。結論:聴診器の使用後と使用前に酒精綿などで拭き取りを行う必要がある。 </p>