Scoring System for Sub classification of Category 3 Calcifications in Soft Copy Diagnostics

  • Konishi Akiko
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Fujii Naoko
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Nakama Tomomi
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Furukawa Hiroko
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Yamanishi Shoko
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Terai Asuka
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Katayama Wakana
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Yoshikawa Emi
    Department of medical technology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Sawai Yuka
    Department of Diagnostic Radiology, Medical Corporation Eijinkai Osaka Breast Clinic
  • Fujita Tomoko
    Department of Breast Surgery, Medical Corporation Eijinkai Osaka Breast Clinic
  • Shiba Eiichi
    Department of Breast Surgery, Medical Corporation Eijinkai Osaka Breast Clinic

Bibliographic Information

Other Title
  • ソフトコピー診断におけるカテゴリー3石灰化細分類の ためのスコアリングシステム

Description

Mammography-guided aspiration mammary tissue biopsy (MG-VAB) is performed to diagnose category (C) 3 or higher calcified lesions that cannot be detected by ultrasound. However, it is important to decide whether biopsy is indicated or not. We have developed a scoring system to classify C3-1 and C3-2 lesions, especially in the recent softcopy diagnosis, which can be difficult to evaluate because of its detailed morphological observation. The J-RADS 4th edition states that “a large number and high density is considered C3-2,” but there was no significant difference in the number and density between benign and malignant cases. The items with significantly higher malignancy rate were: (1) heterogeneity of density, small and large difference in density, shading, and background density, and (2) heterogeneity of density, small and large difference in density, and angle. Using this system, the malignancy rate of C3-1/C3-2 was (1) 11.6%/32.3% and (2) 6.5%/45.8%, making it possible to create a system that is easy to evaluate even for those inexperienced in MG and may help in determining the indication for biopsy.