GIR接合を用いた木質2方向ラーメン構造の設計事例より抽出される諸課題

書誌事項

タイトル別名
  • VARIOUS ISSUES IDENTIFIED IN A CASE STUDY OF BIDIRECTIONAL TIMBER RIGID STRUCTURE WITH GIR JOINTS

この論文をさがす

説明

<p>This paper discusses structural design using a case study of a real six-story hybrid structure project that incorporates a bidirectional timber rigid structure with glued-in rod (GIR) joints. We will calculate the horizontal load-carrying capacity of Timber structures, which has not yet been systematically developed. We also conducted a tri-directional loading test on a full-scale specimen and found that the calculated values corresponded well with the experimental values. Furthermore, a time history response analysis was performed to verify that the design values for the structural coefficient were appropriate.</p>

収録刊行物

参考文献 (1)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘