- Down-Sizing in Analytical Chemistry. Analysis of milligram amounts of bronze reference samples by an internal standard method/ICP-AES.
- 内標準法/誘導結合プラズマ発光分析法による少量青銅標準試料の分析
- ナイ ヒョウジュンホウ ユウドウ ケツゴウ プラズマ ハッコウ ブンセキ ホウ ニ ヨル ショウリョウ セイドウ ヒョウジュン シリョウ ノ ブンセキ
この論文をさがす
抄録
In order to accurately determine major elements (Cu, Sn, Zn and Pb) in milligram amounts of bronze reference samples, an application of ICP-AES using scandium as an internal standard element was investigated. The correlation coefficient of each major element to scandium was above 0.93 and the repeatable precision in measuring the emission intensity ratio of each major element to scandium was 0.10∼0.45% (RSD, %, n=25), which corresponded to 1/3∼1/5 times that obtained without an internal standard. In an analysis with a 10mg amount of the sample, the relative variances for 4 major elements {Relative variance (%)=[(Mfound-Mcert)/Mcert]×100, where Mfound and Mcert are the found and certified values, respectively.} were 0∼−1.4%, except for Pb. On the other hand, those obtained from an analysis with a 5mg or a 2mg amount of sample were −0.8∼−6.3%.