Refinement and application of X-ray diffraction method as the surface roughness analysis.

Bibliographic Information

Other Title
  • X線回折法による表面凹凸の解析方法の改良とその応用
  • Xセン カイセツホウ ニ ヨル ヒョウメン オウトツ ノ カイセキ ホウホウ ノ カイリョウ ト ソノ オウヨウ

Search this article

Description

We had developed the method for measurement of surface roughness using X-ray diffractometer. This method uses the X-ray diffraction (XRD) profiles from the “surface-replicated film” instead of that from the sample itself, which is vaccum-metallized thin metal film on the surface of a sample to replicate surface roughness. Several peaks separated from this profile are calculated exactly to obtain diffraction angle 2θ, intensity I, integrated intensity S, full width at half maximum intensity ω (F.W.H.M.), and some other parameters. Decentering distance x as the height of convexity (x>0) or as the deepness of concavity (x<0) is calculated by the deviation of diffraction angle Δ2θ, and area of “rough” surface is calculated by the integrated intensity. Analytical result of the distance and area is described by these analyzed parameters like an irregular stairway. We studied for measurement to fix particularly appropriate conditions. Consequently, we designated these conditions to measrue surface roughness as follows: surface-replicated film is Au (gold), target is Cu (copper), divergence slit and scattering slit are 1° (X-ray exposed area: 16.2 mm×10.0 mm), receiving slit is 0.3 mm. Then, we measured of electrodeposited hydroxyapatite samples using these compiled conditions. Analytical result of these samples was lead statistically and we were able to find rough surface of electrodeposited cathodes, particle size of deposited hydroxyapatite crystal on the cathodes, and convex area of electrodeposited samples by these data. Though the SEM micrograph gives figures and sizes of samples, it transcribes a fraction of the sample in a vacuum showed narrow than our X-ray diffraction method in air. If you know the surface of samples by SEM as wide as by our method, you will spend over twenty hours for only one or a few of sample. But we can need only 60∼120 minutes for measurement of one sample.

Journal

  • BUNSEKI KAGAKU

    BUNSEKI KAGAKU 51 (9), 707-714, 2002

    The Japan Society for Analytical Chemistry

Citations (1)*help

See more

References(9)*help

See more

Details 詳細情報について

Report a problem

Back to top