- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
-
- Nayatani Y.
- Electrotechnical Laboratory, Osaka Branch
-
- Kurioka Y.
- Electrotechnical Laboratory, Osaka Branch
-
- Sobagaki H.
- Electrotechnical Laboratory, Osaka Branch
Bibliographic Information
- Other Title
-
- 演色性とメタメリズムに関する研究 (その3)
- Spectral power distributons of typical fluorescent lamps with the same chromaticity coordinates as those of the CIE standard illuminant C and with various colorrendering indexes, and their
- 標準光源Cと同一の色度点を有し, 種々の平均演色評価数を有する, けい光灯の分光分布の合成, およびそのメタメリズムへの応用
Search this article
Description
The principal component analysis was applied to the spectral power distributions of actual fluorescent lamps, and three characteristic functions SF1 (λ), SF2 (λ) and SF3 (λ) were derived. Based on the average spectral power distribution J (λ) and these three characteristic functions, reconstituted spectral power distributions of fluorescent lamps JFt (λ) were derived with arbitrary chromaticity coordinates and with arbitrary general color-rendering index by the following equation.<BR>JFt (λ) =J(λ) +k1SF1 (λ) +k2SH2 (λ) +k3SF3 (λ)<BR>By use of these spectral power distributions, the following subjects were discussed;<BR>(1) The maximum value of the general color-rendering index was Rα =93.4 for reconstituted fluorescent lamps with the same chromaticity coordnates as those of the CIE standard illuminant C.<BR>(2) The value of σ2, variance of deviations in spectral power distributions between the test and the reference illuminant, had its minimum corresponding to the maximum value of the general colorrendering index.<BR>(3) Deviations of chromaticity coordinates of eight test object colors for the general color-rendering index were clarified between the CIE illuminant C and each of reconstituted fluorescent lamps with different values of Rα.<BR>(4) On twelve gray object colors which were metameric with respect to the CIE standard illuminant C and the CIE 1931 standard observer, failures of preserving color match among them were discussed under each of the above reconstituted fluorescent lamps. Average color differences ΔEM, the measure of the failure of preserving color matching among metameric object colors, have the following simple relations with Rα for the actual fluorescent lamps.<BR>_??_
Journal
-
- JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
-
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN 55 (8), 481-495, 1971
The Illuminating Engineering Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679057813120
-
- NII Article ID
- 130003757171
-
- ISSN
- 1349838X
- 21851506
- 00192341
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed