Visual Acuity as a Function of Luminance Contrast of Landolt Rings and Adaptation Luminance
-
- Ikeda Koichi
- Faculty of Science and Engineering, Science University of Tokyo
-
- Noda Koji
- TL Yamagiwa Laboratory Inc.
-
- Yamaguchi Shoichiro
- Faculty of Engineering, Tokyo Institute of Technology
Bibliographic Information
- Other Title
-
- ランドルト環視標の輝度対比および順応輝度と視力との関係
- ランドルト カンシ ヒョウ ノ キド タイヒ オヨビ ジュンノウ キド ト シ
Search this article
Description
The purpose of this study is to investigate the visual acuity as a function of the luminance contrast of the test objects and the adaptation lminance. The test objects are Landolt rings with the luminance contrast from 3 to 92%. The observers, all with normal vision, judge the break orientations of the Landolt rings by guessing. Visual experiments are carried out according to the standard method of the visual acuity test. Results obtained are as follows.<BR>(1) The resolvable visual angle θ can be expressed as a function of the lum nance contrast C (%) and the adaptation uminance L (cd/m2), <BR>θ=1.6293C-0.3234 (0.8034C-0.1876+L1/4) 4/L (minutes)<BR>For practical use, following equation is derived as a simple and convenient formula to calculate the resolvable visual angle.<BR>θ=1.7C-1/3 (0.85C-1/5+L1/4) 4/L(minutes)<BR>(2) As the luminance contrast of the test objects can not be discriminated below a certain adaptation luminance, the visual acuity is not defined and the above equations do not hold below this luminance. This threshold luminance is expressed as a function of the luminance contrast; i. e., <BR>L=2.974C-1.7234 (cd/m2)<BR>(3) The visual acuity in the vertical and the horizontal directions are slightly higher than those in the oblique onse irrespective of the luminance contrast of the Landolt rings.
Journal
-
- JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
-
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN 67 (10), 527-533, 1983
The Illuminating Engineering Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679060572800
-
- NII Article ID
- 110001144337
- 130006763128
- 40004319513
-
- NII Book ID
- AN00268860
-
- ISSN
- 1349838X
- 21851506
- 13498398
- 00192341
- 03878805
-
- NDL BIB ID
- 2609216
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- NDL Digital Collections (NII-ELS)
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed