- Study of Electronic Ballast for High Intensity Discharge Lamps
- コウアツ ホウデントウヨウ デンシシキ テントウ カイロ ノ ケンキュウ
この論文をさがす
抄録
High frequency operation of HID lamps causes acoustic resonance phenomenon, and several countermeasures to avoid it have been studied and reported.<BR>We focusing our attention to the balance of stable frequency and destabilizing frequency, experimented to find on what condition the arc is kept stable.<BR>We reached a result that even if some arc destabilizing frequency exists in the lamp current, an unstable condition will not grow so long as its ratio is small enough.<BR>We proposed the rectangular waveform operating method as a concrete operation circuit to apply this experiment result to actual use.<BR>We have found good characteristics in its operation, when applied to a 70W metal halide lamp.<BR>Here, we report our study on it.
収録刊行物
-
- 照明学会誌
-
照明学会誌 72 (2), 85-90, 1988
一般社団法人 照明学会