- Tolerable Range of Illuminance of a Room to Yield Continuity Perception to Outside in Presence of Color Temperature Difference in the Two Spaces
- イロオンド ノ サ オ コウリョシタ シツナイ カラ コガイ オ ミタ バアイ
この論文をさがす
抄録
Continuity perception between two spaces can be obtained in general by adjusting the illuminance level of one of the spaces, when we say that the recognized visual spaces of illumination of the twospaces were made equal. This continuity can be experienced, for example, when an observer in a room looks outside through a window and the illuminance of the room is properly adjusted. There exists a range of illuminance within which continuity perception is assured. In the present experiment the range was measured when the color temperature of the room was systematically changed so that there were various differences in the color temperature between the room and the outside. The experiment was carried out during day time, and the weather outside varied greatly both during and between the experimental sessions. The results show that the range, when expressed in a specific form of outside illuminance and room illuminance, was constant regardless of the color temperature difference. The upper limits as well as the lower limits of the range slightly increased as the color temperature of the room became lower than that of the outside.
収録刊行物
-
- 照明学会誌
-
照明学会誌 81 (8), 621-627, 1997
一般社団法人 照明学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679061718784
-
- NII論文ID
- 130006765491
- 20000334795
-
- NII書誌ID
- AN00268860
-
- ISSN
- 1349838X
- 21851506
- 00192341
- http://id.crossref.org/issn/00192341
-
- NDL書誌ID
- 4266507
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可