高濃度鉄・マンガン含有地下水の膜ろ過処理に関する基礎研究

書誌事項

タイトル別名
  • STUDIES ON MEMBRANE FILTRATION TREATMENT OF GROUND WATER INCLUDED HIGH CONCENTRATION OF Fe AND Mn.

この論文をさがす

説明

Membrane filtration of ground water, which included high concentration of Fe, Mn and dissolved-SiO2, was investigated using 5 kinds of membrane. In the case of air oxidation, particle size of oxide was 0.03-0.1μm, and its coagulation state was poor. So, perfect removal of Fe by MF membrane was difficult without Alum dose.<BR>In the case of chlorine oxidation, particle size of oxide was 0.01-0.03μm, and the removal of Fe by membrane (pore size below 0.1μm) is perfect because of high coagulation state of oxide. The removal of Mn by MF and UF membrane after chlorine oxidation was 80-90% but concentration of Mn was not below 0.01mg/l. The concentration of Mn by the combination of Mn-sand filtration after membrane filtration reaches below 0.01mg/l. The increase of filtration resistance of UF and MF membrane depends on the pore size and the coagulation state of oxide by the difference of oxidation method.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1390282679089823360
  • NII論文ID
    130003775551
  • DOI
    10.11532/proes1992.30.311
  • ISSN
    1884829X
    13415115
  • データソース種別
    • JaLC
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ