Effects of Plating Conditiony on Reduction Efficiencs of Electroless Cobalt Plating Baths

Bibliographic Information

Other Title
  • 無電解コバルトメッキ浴の還元効率に及ぼすメッキ条件の影響
  • コバルトおよびその合金の無電解メッキに関する研究 (第5報)

Search this article

Description

Effects of plating conditions on utilization of sodium hypophosphite (reduction efficiency) and plating rate in caustic alkaline electroless cobalt plating baths were investigated.<br>Although the reduction efficiencies greatly depended upon pH of bath, type and concentration of complexing agent, and concentration of bath components, they were usually kept in the range of 30-40% under the standard plating condition.<br>The tartrate bath gave higher plating rates and reduction efficiencies than those of citrate bath, but it gave more variable reduction efficiencies owing to its lower stability of the bath as compared with citrate bath.<br>As compared with other electroless nickel plating baths having the similar compositions to that of caustic alkaline citrate bath, the cobalt plating bath gave considerably lower plating rates, but higher reduction efficiencies.

Journal

Details 詳細情報について

  • CRID
    1390282679092494976
  • NII Article ID
    130003993701
  • DOI
    10.4139/sfj1950.18.180
  • ISSN
    18843395
    00260614