- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Electroendosmotic liquid flows in various wide and narrow pH range isoelectric focusing gel prepared with IsoGel and Agarose IEF.
-
- Kobayashi Sadao
- Department of Bioorganic Chemistry, College of Environmental Health, Azabu University
-
- Yoshihara Eiji
- Department of Bioorganic Chemistry, College of Environmental Health, Azabu University
-
- Suzuki Jun
- Department of Bioorganic Chemistry, College of Environmental Health, Azabu University
Bibliographic Information
- Other Title
-
- 広域および狭域両性担体を用いた薄層アガロース等電点電気泳動における液流
Search this article
Description
The electroendosmotic behavior of IsoGel and Agarose IEF was determined in a series of various wide and narrow pH range electrofocusing experiments in which glucose served as marker substance.<br>In IsoGel its liquid flow caused towards the anode in all wide and narrow pH range electrofocusing. The strength of segmetal liquid flow was proportional to voltage distribution across the gel. The pH gradients obtained in IsoGel when using same wide pH range ampholyte has markedly low pH values than that of Agerose IEF at acidic region.<br>In Agarose IEF its liquid fow behavior differed in wide and narrow pH range electrofocusing. In the case of wide pH range electrofocusing its liquid flow reversed towards the anode at pH 5.5∼6 region in the foucsed gels. The other hand, in narrow pH range electrofocusing the direction of liquid flow was differed with pH range of ampholyte. In higher pH range than Amopholine 5-7 its liquid flow coused towards the cathode and in lower pH range than Ampholine 4-6 reversed towards the anode. The direction and the streght of liquid flow in narrow pH range Agarose IEF depends on the pH distribution in the focused gel. The pH curves obtained in Agarose IEF when using same narrow pH range Ampholyte were slightly higher than that of IsoGel.
Journal
-
- SEIBUTSU BUTSURI KAGAKU
-
SEIBUTSU BUTSURI KAGAKU 31 (6), 423-429, 1987
Japanese Electrophoresis Society
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679179927680
-
- NII Article ID
- 130003606811
-
- ISSN
- 13499785
- 00319082
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed