Stress distribution in the screw type temporary anchorage device during loading with orthodontic force
-
- Oyazato Yoshimasa
- Department of Orthodontics, Osaka Dental University
-
- Okashita Shintaro
- Department of Orthodontics, Osaka Dental University
-
- Kaoru Inami
- Graduate School of Dentistry (Department of Orthodontics), Osaka Dental University
-
- Kambara Toshiyuki
- Department of Orthodontics, Osaka Dental University
-
- Kawamoto Tatsuo
- Department of Orthodontics, Osaka Dental University
Bibliographic Information
- Other Title
-
- 矯正力荷重時におけるスクリュー型Temporary Anchorage Device (TAD)の内部発生応力について
- キョウセイリョク カジュウジ ニ オケル スクリューカタ Temporary Anchorage Device TAD ノ ナイブ ハッセイ オウリョク ニ ツイテ
Search this article
Abstract
We used three-dimensional finite element analysis to investigate how the shape of the screw type temporary anchorage device (TAD) and the direction of traction affected stress distribution in the screw during loading with orthodontic force. Four different shapes of screws, all made of titanium, were tested. The simulated alveolar bone had 1mm of cortical bone, with the remainder being cancellous bone. <br> Finite element models were prepared using a three-dimensional solid modeler. Stress was measured during loading of the TAD in five directions: directed upward 45 and 22.5 degrees relative to horizontal, 90 degrees to the long axis of the screw (perpendicular), and downward 22.5 and 45 degrees relative to horizontal. The data were subjected to linear static analysis using a universal structure analysis program.<br> In all types of TAD tested, the maximum principal stress was found to be directed to the cortical bone on the side opposite the load. We found that internal stress was extremely high with the slender cylinder type TAD, and lowest with the conical type. There was no significant difference between the cylinder and short cylinder types. We also found that internal stress was lowest at a traction angle of 45 degrees upwards for each type of TAD.<br> Our results suggest that the internal stress of the screw type TAD is affected by screw diameter, and that internal stress is lower when traction is applied upward on the screw.
Journal
-
- Shikaigaku
-
Shikaigaku 69 (3_4), 151-159, 2006
Osaka Odontological Society
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679186075136
-
- NII Article ID
- 110005717033
-
- NII Book ID
- AN00099810
-
- ISSN
- 2189647X
- 00306150
-
- NDL BIB ID
- 8585422
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed