Dependence of EMG-Reaction Times of the Rectus Femoris on Position Changes of the Hip Joint

  • IRIS NORIKAZU
    Department of Rehabilitation Medicine, Institute of Balneology, Tohoku University School of Medicine
  • NAKAMURA RYUICHI
    Department of Rehabilitation Medicine, Institute of Balneology, Tohoku University School of Medicine

Bibliographic Information

Other Title
  • Role of the Joint Capsule

Search this article

Description

Tohoku J. exp. Med., 1980, 131 (2), 207-208 - EMG-reaction times (EMG-RTs) of the rectus femoris in midposition (M) and internally rotated position (IR) of the right hip joint were examined in nine control subjects and nine patients who had lost most of the capsule of a hip joint after total hip joint replacement procedure. In both groups EMG-RTs of the rectus femoris were faster at IR than at M. The difference of EMG-RTs between M and IR was essentially the same in the two groups. It is assumed that information from proprioceptors in the joint capsule may not play an important role in postural dependence of EMG-RTs of the muscle.

Journal

Details 詳細情報について

Report a problem

Back to top