Effects of Precipitates and Albumin in Simulated Body Fluids on Pin-on-Disk Wear Behavior of Biomedical Co-Cr-Mo Alloys
-
- Ueda Kyosuke
- Department of Materials Processing, Tohoku University
-
- Kasamatsu Motoka
- Department of Materials Processing, Tohoku University
-
- Tanno Masanori
- Department of Materials Processing, Tohoku University
-
- Ueki Kosuke
- Department of Materials Processing, Tohoku University
-
- Geringer Jean
- Department STBio/Bio-tribocorrosion, Center for Biomedical and Healthcare Engineering, Ecole Nationale Supérieure des Mines de Saint-Etienne
-
- Narushima Takayuki
- Department of Materials Processing, Tohoku University
書誌事項
- 公開日
- 2016
- 資源種別
- journal article
- DOI
-
- 10.2320/matertrans.mi201518
- 公開者
- 公益社団法人 日本金属学会
この論文をさがす
説明
<p>Pin-on-disk wear tests using Co-Cr-Mo (CCM) alloy pins and disks were conducted in 0.14 M NaCl solutions with and without albumin. To clarify the effect of precipitates in the CCM alloys on the alloy wear behavior, as-received (having precipitates) and solution-treated (having no precipitates) CCM alloys were used as specimens. Friction coefficients during wear testing were measured. After the wear testing, the mass loss of pins and disks, wear tracks on the disks, and the wear debris were examined using scanning electron microscopy (SEM) and laser microscopy (LM). The concentration of metallic ions in solution was analyzed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). In the solution without albumin, the friction coefficient increased with increasing sliding time and discontinuous wear grooves with attached and detached sections were observed, indicating that adhesive wear was dominant. On the other hand, in the solution with albumin, the friction coefficient was constant independent of the sliding distance and continuous wear grooves were observed, indicating that abrasive wear was dominant. High amounts of mass loss were detected from the as-received alloys in the albumin solution, and it is theorized that the wear debris (including precipitates) enhanced the third-body wear. The concentration of Cr ions in solution was lower than the expected values based on the alloy composition. In the solution with albumin, it was thought that the Cr ions bonded with the albumin, increasing the amount of available Cr ions in solution.</p>
収録刊行物
-
- MATERIALS TRANSACTIONS
-
MATERIALS TRANSACTIONS 57 (12), 2054-2059, 2016
公益社団法人 日本金属学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679230900736
-
- NII論文ID
- 130005284489
-
- NII書誌ID
- AA1151294X
-
- ISSN
- 13475320
- 13459678
-
- HANDLE
- 10097/00127768
-
- NDL書誌ID
- 027758527
-
- 本文言語コード
- en
-
- 資料種別
- journal article
-
- データソース種別
-
- JaLC
- IRDB
- NDLサーチ
- Crossref
- CiNii Articles
- KAKEN
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可

