Determination of Sulpiride in Human Urine Using Excitation-Emission Matrix Fluorescence Coupled with Second-order Calibration
-
- NIE Jin-Fang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- WU Hai-Long
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- XIA A-Lin
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- ZHU Shao-Hua
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- BIAN Ying-Chao
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- LI Shu-Fang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
-
- YU Ru-Qin
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University
この論文をさがす
抄録
This paper proposes a new and effective approach for the quantitative analysis of sulpiride, a significant antipsychotic drug, in human urine samples by the incorporation of excitation-emission matrix (EEM) fluorescence and second-order calibration methodologies based on the alternating fitting residue (AFR) and self-weighted alternating trilinear decomposition (SWATLD) algorithms. With the application of a second-order advantage, the proposed strategy could be utilized for a direct concentration determination of sulpiride with a simple pretreatment step, even in the presence of serious natural fluorescent interferences. The average recoveries of sulpiride in complex urine samples by using AFR and SWATLD with an estimated component number of three were 101.2 ± 2.1 and 94.4 ± 0.7%, respectively. Moreover, the accuracy of the two algorithms was also evaluated through elliptical joint confidence region (EJCR) tests as well as the figures of merit, such as sensitivity (SEN), selectivity (SEL) and limit of detection (LOD). The experimental results demonstrated that both algorithms, as promising quantitative alternatives, have been satisfactorily applied to the determination of sulpiride in human urine, but the performance of AFR was slightly better than that of SWATLD.
収録刊行物
-
- Analytical Sciences
-
Analytical Sciences 23 (12), 1377-1382, 2007
社団法人 日本分析化学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679233767680
-
- NII論文ID
- 10020012598
-
- NII書誌ID
- AA10500785
-
- ISSN
- 13482246
- 09106340
-
- NDL書誌ID
- 9286633
-
- Web Site
- http://id.ndl.go.jp/bib/9286633
- https://ndlsearch.ndl.go.jp/books/R000000004-I9286633
- https://link.springer.com/content/pdf/10.2116/analsci.23.1377.pdf
- https://link.springer.com/article/10.2116/analsci.23.1377/fulltext.html
- http://www.jstage.jst.go.jp/article/analsci/23/12/23_12_1377/_pdf
- https://search.jamas.or.jp/link/ui/2008118186
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可