Atmospheric Concentrations of Sulfur Dioxide, Nitrogen Oxides, Ammonia, Hydrogen Chloride, Nitric Acid, Formic and Acetic Acids in the South of Vietnam Measured by the Passive Sampling Method

DOI PDF Web Site Web Site Web Site View 1 Remaining Hide 3 Citations 11 References

Search this article

Abstract

A passive sampling method was applied to measure the concentrations of air pollutants, such as sulfur dioxide, nitrogen oxides, ammonia, hydrogen chloride, and nitric, formic and acetic acids, in the ambient air at four test sites in the southern region of Vietnam. The monthly averages and the average concentrations of air pollutants during the period from July 2001 to September 2002 are reported here. The concentrations of air pollutants varied widely, depending on the test sites and the sampling periods. The average concentrations of sulfur dioxide in the air during the period from July 2001 to September 2002 at the four test sites were 3.3 - 16.9 ppb, and those of nitrogen dioxide were 5.4 - 12.8 ppb. The concentrations of nitrogen monoxide and hydrogen chloride were very low at all of the test sites. The observed concentrations of all of the above-mentioned pollutants were lower than those of the Vietnamese standards of air pollutants.

Journal

  • Analytical Sciences

    Analytical Sciences 20 (1), 213-217, 2004

    The Japan Society for Analytical Chemistry

Citations (3)*help

See more

References(11)*help

See more

Details 詳細情報について

Report a problem

Back to top