Chemically Modified Carbon Paste Electrode for the Potentiometric Determination of Dicylomine Hydrochloride in Batch and in FIA Conditions

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献1件 参考文献79件

この論文をさがす

抄録

A carbon-paste electrode for dicyclomine hydrochloride (DcCl) was prepared and fully characterized in terms of composition, life span, usable pH range and temperature. The electrode was applied to the potentiometric determination of dicylominium ion in its pure state and in pharmaceutical preparations in batch and flow injection conditions and in biological fluids using standard additions method. The electrode is based on a mixture of two ion-exchangers, namely, dicyclominium-phosphomolybdate and dicylominium-tetraphenylborate, dissolved in dioctyl phthalate as pasting liquid. The modified electrode showed a near-Nernstian slope of 58 ± 2 mV over the concentration range of 1.2 × 10-5 - 1.6 × 10-2 M with an average recovery of 97 - 102% and a RSD of 0.090 - 1.00. The electrode exhibits good selectivity for DcCl with respect to a large number of inorganic cations, sugars, amino acids and organic substances of biological fluids. Potentiometric titrations of DcCl with several titrants have been monitored using this modified carbon paste electrode as an end-point indicator electrode.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 20 (6), 911-916, 2004

    社団法人 日本分析化学会

被引用文献 (1)*注記

もっと見る

参考文献 (79)*注記

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘

ページトップへ