- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Development of Tetrahydrofuran/Water Optical Waveguide and Its Application to the Observation of Extraction Behavior of 1-Anilino-8-naphtalene Sulfonate at the Tetrahydrofuran/Water Interface
-
- TAKIGUCHI Hiromi
- Graduate School of Engineering, The University of Tokyo
-
- ASANUMA Soto
- Department of Chemistry and Chemical Biology, Gunma University
-
- KAMIYAMA Junya
- Department of Chemistry and Chemical Biology, Gunma University
-
- MURATA Hiroyasu
- Department of Chemistry and Chemical Biology, Gunma University
-
- HASEGAWA Yuki
- Department of Chemistry and Chemical Biology, Gunma University
-
- YOSHIZAWA Satoshi
- Department of Chemistry and Chemical Biology, Gunma University
-
- HOTTA Hiroki
- Graduate School of Maritime Sciences, Kobe University
-
- ODAKE Tamao
- Graduate School of Engineering, The University of Tokyo
-
- UMEMURA Tomonari
- School of Life Sciences, Tokyo University of Pharmacy and Life Sciences
-
- SATO Kiichi
- Department of Chemistry and Chemical Biology, Gunma University
-
- TSUNODA Kin-ichi
- Department of Chemistry and Chemical Biology, Gunma University
Bibliographic Information
- Other Title
-
- Development of Tetrahydrofuran/Water Optical Waveguide and Its Application to the Observation of Extraction Behavior of l-Anilino-8-naphtalene Sulfonate at the Tetrahydrofuran/Water Interface
Search this article
Description
A stable two-phase sheath flow using tetrahydrofuran (THF) for an inner flow and water for an outer flow was formed in a glass capillary, and worked as a stable liquid-core/liquid-cladding optical waveguide (THF/water LLW). Although THF and water were miscible with any ratio, the length of the stable THF/water LLW at 0.9 – 2.1 cm s−1 reached at least 150 mm. The THF/water LLW was applied to the observation of extraction behavior of solvatochromic fluorescence dye, 1-anilino-8-naphtalene sulfonate (ANS), through the THF/water interface. ANS was added to the water phase (clad solution) and its fluorescence, which was excited with the guided light (355 nm) through the LLW, was observed by changing the position of the detector. While the ANS stayed in the region of 70% THF to the end of the LLW without the addition of cationic surfactant, hexadecyltrimethylammonium ion (CTA+) at pH 3 and 11, the ion-pair of ANS and CTA+ was extracted into the higher concentration region of THF with the addition of CTA+ at pH 11.
Journal
-
- Analytical Sciences
-
Analytical Sciences 33 (4), 449-455, 2017
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679236655104
-
- NII Article ID
- 130005587950
-
- NII Book ID
- AA10500785
-
- ISSN
- 13482246
- 09106340
-
- HANDLE
- 20.500.14094/90004291
-
- NDL BIB ID
- 028100086
-
- PubMed
- 28392518
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- IRDB
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- KAKEN
- OpenAIRE
-
- Abstract License Flag
- Disallowed