Cyclohexane as an Alternative Vapor of Carbon Tetrachloride for the Assessment of Gas Removing Capacities of Gas Masks.
-
- FURUSE Mitsuya
- National Institute of Industrial Health
-
- KANNO Seiichiro
- National Institute of Industrial Health
-
- TAKANO Tsuguo
- National Institute of Industrial Health
-
- MATSUMURA Yoshimi
- Kawasaki Respirator Test Laboratory
Search this article
Description
An alternative vapor was explored to replace carbon tetrachloride (CCl4) for testing breakthrough times of cartridges and canisters of gas masks in the National Approval Test of Respirators. Cyclohexane was single out as a candidate for the alternative vapor out of six vapors: trichloroethylene, n-pentane, n-hexane, n-heptane, toluene and cyclohexane from the viewpoints of similarity of vapor pressure and water-solubility to CCl4, lower toxicity than CCl4, and technical feasibility in generating an airflow of 30 L/min containing the vapor ranging from 300 to 5000 ppm. Breakthrough times of cartridges and canisters were examined by generating cyclohexane vapor in a test airflow of 30 L/min in comparison with CCl4 vapor under various test conditions with different vapor concentrations and relative humidities (RH). As the results, the breakthrough times of the cartridges and canisters for cyclohexane were found to almost coincide with those for CCl4 under all examined range of concentrations and RH. By an increase of humidity from 50%RH to 80%RH, the cartridges showed significant shortening of breakthrough times for both of CCl4 and cyclohexane, but the susceptibility of the breakthrough time of cyclohexane to humidity was also similar to that of CCl4. It was, therefore, concluded that cyclohexane can be recommended as the alternative vapor of CCl4 for testing the breakthrough times of gas mask cartridges and canisters in the National Approval Test.
Journal
-
- Industrial Health
-
Industrial Health 39 (1), 1-7, 2001
National Institute of Occupational Safety and Health
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679257696384
-
- NII Article ID
- 130003550971
- 40005265709
-
- NII Book ID
- AA00672955
-
- COI
- 1:CAS:528:DC%2BD3MXhtlyitrg%3D
-
- ISSN
- 18808026
- 00198366
- http://id.crossref.org/issn/00198366
-
- NDL BIB ID
- 5994714
-
- PubMed
- 11212284
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
-
- Abstract License Flag
- Disallowed