表面汚染密度測定における走査条件と検出能力との関係

書誌事項

タイトル別名
  • Variation of Detection Ability with Scanning Method on Surface Survey of Radiological Density
  • ヒョウメン オセン ミツド ソクテイ ニ オケル ソウサ ジョウケン ト ケンシュツ ノウリョク ト ノ カンケイ

この論文をさがす

説明

The scanning method with GM survey meter is useful for detection of surface radiological density. The detection ability is varied with several parameters; those are the distance between the sample and the window of GM tube, the scanning speed and the background dose rates. We made an experimental system. In that system, a radiation source can be moved at any constant velocity with a linear scanning device. The obtained data shows that the change of count rate has some patterns due to each scanning velocity. The count rate increased with the source coming closer, and decreased with the source moving away. The maximum count rate under the scanning condition, those are 5 mm distance and 50 mm/s scanning velocity, point source on a stainless steel plate was 23% of the count rate on the fixed source. The detection ability in various scanning conditions was evaluated from the measured data. As a result, it was confirmed to be able surely to detect the lower level of the surface radiological density limit by means of the scanning condition applied to the routine work, 5 mm distance and 50 mm/s scanning velocity.

収録刊行物

  • 保健物理

    保健物理 44 (3), 304-312, 2009

    一般社団法人日本保健物理学会

被引用文献 (2)*注記

もっと見る

参考文献 (10)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ