火力発電設備の定期検査と余寿命診断技術

書誌事項

タイトル別名
  • Content of regular inspection and technique of remaining life assessment on fossil fuel-fired power plant.
  • カリョク ハツデン セツビ ノ テイキ ケンサ ト ヨジュミョウ シンダン ギ

この論文をさがす

抄録

Approximately 60% of the total power generating capacity in Japan is occupied by fossil fuel-fired power plants.<BR>As such, it is highly important that these plants be efficiently used so as to meet the present and future load-growth requirements.<BR>To maintain the reliability and performance of these plants, it is required to inspect the equipment and assess the remaining life of the plants in a strict manner.<BR>Moreover, the maintenance and improvement of plants through this assessment is a vital factor in assuring the stable supply of electricity.<BR>This report describes the content of regular inspection, current status and items pertaining to the remaining life assessment on fossil fuel-fired power plants.

収録刊行物

  • 燃料協会誌

    燃料協会誌 69 (5), 320-327, 1990

    一般社団法人 日本エネルギー学会

詳細情報 詳細情報について

問題の指摘

ページトップへ