有限振幅超音波を用いた閉口クラックからの2次高調波の検出

書誌事項

タイトル別名
  • Detection of Second Harmonic Wave from the Closed Crack Using Finite amplitude Ultrasonic Wave

この論文をさがす

抄録

Detection method for the closed crack existed in the glass plate using finite amplitude ultrasonic guided wave is described. The received signal is analyzed by the wavelet transform to identify the mode of the guided wave using group velocity dispersion curves. As the results, finite amplitude Rayleigh wave propagation is identified. Using the finite amplitude Rayleigh wave, increase in 6dB of the second harmonic components generated from a closed crack in the glass plate is observed. Rapid increase of the second harmonic component at the condition that width of closed crack, less than 2nm, is equal to the vibration amplitude of Rayleigh wave is also found out. Potential of closed crack detection is clarified by the use of finite amplitude guided wave system.

収録刊行物

被引用文献 (6)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ