- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Development of a novel GC/MS database for simultaneous determination of hazardous chemicals
-
- KADOKAMI Kiwao
- Kitakyushu City Institute of Environmental Sciences
-
- TANADA Kyoko
- Kitakyushu City Institute of Environmental Sciences
-
- TANEDA Katsuyuki
- Shimadzu Corporation
-
- NAKAGAWA Katsuhiro
- Shimadzu Corporation
Bibliographic Information
- Other Title
-
- 有害化学物質一斉分析用ガスクロマトグラフィー/質量分析法データベースの開発
- ユウガイ カガク ブッシツ イッセイ ブンセキヨウ ガス クロマトグラフィー シツリョウ ブンセキホウ データベース ノ カイハツ
- Development of a novel database for simultaneous determination of hazardrous chemicals
Search this article
Description
A novel GC/MS database for the simultaneous analysis of hazardous chemicals in the environment and food samples was developed. Since GC retention-time data and calibration curves other than mass spectra are registered into the database, an identification and determination of the chemicals in the database can be performed for a short time. By using n-alkanes as retention indices, under the same GC conditions, the retention times of the registered chemicals in samples were exactly predicted with an error for less than 3 seconds; by combining exact predict retention times and reverse searches, reliable identification was completed. Moreover, the registered substances also appeared in the sphere of 1% of the predicted retention times under different programmed temperature conditions and different carrier gas linear velocities. In an examination of the determination ability, by adjusting the GC inlet, the column, and the tuning conditions using the GC/MS performance standards, it was possible to produce a relative standard deviation of the determination values to be 20% or less, except for a part of high-polarity materials, such as pentachlorophenol and benzidine, which are very easy to adsorb on a column. More than 90% of the chemicals in the database could be detected at 100 or less pg, and it exhibited a practically sufficient sensitivity. From these results, it was confirmed that more than 1000 hazardous chemicals can be simultaneously determined without standards by the database system. The database, therefore, can be applied to evaluate the overall safety of environment media and foodstuff.<br>
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 53 (6), 581-588, 2004
The Japan Society for Analytical Chemistry
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679330871680
-
- NII Article ID
- 110002905402
-
- NII Book ID
- AN00222633
-
- COI
- 1:CAS:528:DC%2BD2cXltFeksr8%3D
-
- NDL BIB ID
- 6993749
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- NDL Digital Collections (NII-ELS)
- CiNii Articles
-
- Abstract License Flag
- Disallowed