Determination of Trace Amounts of Elements in High-Purity Iron Steels and Cr-Fe Alloy by ICP-OES after Anion-Exchange Separation

Bibliographic Information

Other Title
  • 陰イオン交換分離/誘導結合プラズマ発光分光分析法による高純度鉄及び鋼,クロム‐鉄合金中の微量元素の定量
  • 陰イオン交換分離/誘導結合プラズマ発光分光分析法による高純度鉄及び鋼,クロム-鉄合金中の微量元素の定量
  • インイオン コウカン ブンリ ユウドウ ケツゴウ プラズマ ハッコウ ブンコウ ブンセキホウ ニ ヨル コウジュンドテツ オヨビ コウ クロム テツ ゴウキン チュウ ノ ビリョウ ゲンソ ノ テイリョウ

Search this article

Description

A method for the determination of a μg g−1 levels of 8 elements in high-purity iron, low-alloy steels, Cr-Fe alloy, and tool steels has been developed. In matrix separation, iron and chromium in the sample solution were passed through a strongly basic anion-exchange resin column with 2 M HF solution. The 8 elements adsorbed on resin, such as Hf, Mo, Nb, Sn, Ta, Ti, W, Zr, were eluted by a nitric acid -hydroperoxide solution and determined by ICP-OES simultaneously. This method could be employed for the analysis of tool steel containing large amount of molybdenum.<br>

Journal

  • BUNSEKI KAGAKU

    BUNSEKI KAGAKU 54 (11), 1039-1045, 2005

    The Japan Society for Analytical Chemistry

Citations (6)*help

See more

References(6)*help

See more

Details 詳細情報について

Report a problem