6,8,15,17-テトラメチル-ジベンゾ-5,9,14,18-テトラアザシクロテトラデセンを用いる銅(II)の吸光光度定量

書誌事項

タイトル別名
  • 6,8,15,17‐テトラメチル‐ジベンゾ‐5,9,14,18‐テトラアザシクロテトラデセンを用いる銅(II)の吸光光度定量
  • Spectrophotometric determination of copper (II) with 6, 8, 15, 17-tetramethyl-dibenzo-5, 9, 14, 18-tetraazacyclotetradecen
  • 6 8 15 17 テトラメチルージベンゾー5 9 14 18 テトラアザシク

この論文をさがす

抄録

6, 8, 15, 17-Tetramethyl-dibenzo-5, 9, 14, 18-tetraazacyclotetradecen was used to the determination of copper(II). The molar absorptivity of the 1: 1 copper chelate was 4.65×104l mo1-1 cm-1 at 381 nm. 3 ml of copper solution {(0.55)×10-5 M} was taken in a 10-ml volumetric flask, and 6 ml of 1.05×10-4 M reagent solution and 1 ml of 0.1 M acetate buffer solution (pH 4.7) were added. The mixture was filled up to 10 ml with water. After standing for 40 min at room temperature, the absorbance was measured at 381 nm against the reagent blank. Beer's law holds up to 1.8×10-5 M of copper. The presence of nickel (>10-6 M) and cobalt, iron (II) (_??_10-7 M) causes an error. By using the reagent, copper in aluminum alloy was determined. Aluminum samples {(20300)mg} were dissolved in 5 ml of aqua regia. Iron must be removed preliminary by extraction with MIBK at 6 M hydrochloric acid. Analytical results of copper in No. 1 AV859 (4.5%), No. 8 BV808 (2.7%), High power Al(D), Nikkei 1970 and HKI were 4.26%, 2.61%, 3.75%, 2.78% and 0.147%, respectively. And their recovery were 98.0%, 102.0%, 98.6%, 96.9% and 98.8%, respectively.

収録刊行物

  • 分析化学

    分析化学 28 (7), 440-442, 1979

    公益社団法人 日本分析化学会

被引用文献 (3)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘