Determination of Impurities in 17.BETA.-Estradiol Reagent by HPLC with Charged Aerosol Detector
-
- Yamazaki Taichi
- Organic Standards Section 1, Organic Analytical Chemistry Division, National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
-
- Ihara Toshihide
- Measurement standards System Division, National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
-
- Nakamura Satoe
- Organic Standards Section 1, Organic Analytical Chemistry Division, National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
-
- Kato Kenji
- Organic Standards Section 1, Organic Analytical Chemistry Division, National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
Bibliographic Information
- Other Title
-
- 荷電化粒子検出器を用いた高速液体クロマトグラフィーによる17β-エストラジオール試薬中の微量成分の定量
- カデンカ リュウシ ケンシュツキ オ モチイタ コウソク エキタイ クロマトグラフィー ニ ヨル 17v-エストラジオール シヤク チュウ ノ ビリョウ セイブン ノ テイリョウ
Search this article
Description
The charged aerosol detector (CAD) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for quantification. We tried to use CAD for the quantification of impurities in a 17β-estradiol reagent. This detector could not analyze a high-concentration sample because of a baseline noise. The component of 17β-estradiol was removed by using a valve-switching device. Quantification of impurities in 17β-estradiol reagent was determined by a calibration curve of 17β-estradiol (USP). The results of quantification used by CAD with the calibration curve of 17β-estradiol were compared with those used by UV with the calibration curve of each standard of impurity. There was correspondence between the results of quantification using CAD and UV. By this result, we confirmed that CAD is useful in analyzing some impurities in the 17β-estradiol reagent.
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 59 (3), 219-224, 2010
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679332923264
-
- NII Article ID
- 10025981259
-
- NII Book ID
- AN00222633
-
- COI
- 1:CAS:528:DC%2BC3cXltFKrtr8%3D
-
- NDL BIB ID
- 10612818
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed