書誌事項
- タイトル別名
-
- Pressure Measurement by Ruby Fluorescence Method.
この論文をさがす
説明
Method of pressure measurement by ruby fluorescence in a diamond-anvil cell at relatively lower pressure is described. Anisotropy of sensing ruby fluorescence and its effect for the accurate pressure measurement are also discussed. Non-hydrostaticity is estimated by the fluorescence of two rubies which have different crystal orientations. Annealing of sensing ruby is effective for improving the accuracy of pressure measurement.
収録刊行物
-
- 高圧力の科学と技術
-
高圧力の科学と技術 3 (1), 87-89, 1994
日本高圧力学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679358658176
-
- NII論文ID
- 130001598642
-
- NII書誌ID
- AN10452913
-
- ISSN
- 13481940
- 0917639X
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可