An Optimality of k-out-of-n Monitoring System with Variable Thresholds
-
- TACHIKAWA Kan
- 電気通信大学大学院電子情報学専攻(現):(株)東芝
-
- SUZUKI Kazuyuki
- 電気通信大学電子情報学科
Bibliographic Information
- Other Title
-
- 可変しきい値をもつk-out-of-nモニタリングシステムの最適性
- カヘン シキイチ オ モツ K-out-of-n モニタリング システム ノ
Search this article
Abstract
The bigger and more complex a system becomes, the more difficult to identify its true condition:whether it is in good state or bad state. Conditioning monitoring maintenance which utilizes a monitor to get information on the true state plays a role in such an occasion. But, a monitor has two kinds of faults;"no alarm(fail to operate)"when the system is in a bad state, and"raising alarm(fail to idle)"when in a good state. This article deals with a monitoring system which consists of multiple monitors with variable thresholds for raising alarm. A sufficient condition is shown under which the optimal maintenance policy is given by k-out-of-n monitoring systems in the terms of expected risk in the case where n equals 3 and 4. Also, the optimal thresholds of multiple monitors are given by an equal value for every monitor.
Journal
-
- The Journal of Reliability Engineering Association of Japan
-
The Journal of Reliability Engineering Association of Japan 20 (3), 158-166, 1998
Reliability Engineering Association of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679428703744
-
- NII Article ID
- 110004002899
-
- NII Book ID
- AN10540883
-
- ISSN
- 24242543
- 09192697
-
- NDL BIB ID
- 4423022
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed