Consideration of Stretchable Dry Electrodes for Smart Shirts Aimed for Biological Signal Monitoring

Bibliographic Information

Other Title
  • 生体信号モニタリング用スマートシャツに適した伸縮性ドライ電極の検討
  • セイタイ シンゴウ モニタリングヨウ スマートシャツ ニ テキシタ シンシュクセイ ドライ デンキョク ノ ケントウ

Search this article

Description

<p>Dry electrodes of a smart shirt for measuring biological signals were prepared by the additive printing method using a stretchable conductive paste with Ag fillers loading. Interfacial impedance between the electrode and skin depended on the contact pressure of electrode and the moisture of stratum corneum. When moisture of stratum corneum was more than 30%, ECG could be measured using the stretchable electrodes printed on a compression shirt. However, noise signal in the ECG signal increased when the moisture of stratum corneum was less than 30%. To solve this problem, we propose to use additional electrodes made of an electrically conductive kneaded rubber.</p>

Journal

Citations (1)*help

See more

References(2)*help

See more

Details 詳細情報について

Report a problem

Back to top