書誌事項
- タイトル別名
-
- Validation Studies of ‘OC-Hemocatch’ for the Forensic Identification of Human Blood
説明
‘OC-Hemocatch’, an immunochromatographic test for the detection of fecal occult blood was evaluated for the forensic identification of human blood. ‘OC-Hemocatch’ showed positive results for human blood to a dilution of 1:500,000 and provides the strongest detection line for a dilution of 1:20,000. On the other hand, the human blood diluted to 1:100 was negative for ‘OC-Hemocatch’ because of the high dose hook effect. While heating at over 150°C, long term exposing to sunlight, washing and bleaching of bloodstains prevented the detecting of human hemoglobin using ‘OC-Hemocatch’, contamination of blood with various body fluids did not affect it. Furthermore, ‘OC-Hemocatch’ detected human hemoglobin from old bloodstains stored for 15 years at room temperature when 5% ammonia was used for extraction. These results demonstrate that ‘OC-Hemocatch’ can be effectively applied to forensic identification of human blood.<br>
収録刊行物
-
- 日本鑑識科学技術学会誌
-
日本鑑識科学技術学会誌 7 (2), 159-165, 2003
日本法科学技術学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679459778816
-
- NII論文ID
- 130004853086
-
- ISSN
- 18822827
- 13428713
- http://id.crossref.org/issn/13428713
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可