北米西岸航路コンテナ船内における空気環境の測定結果について

書誌事項

タイトル別名
  • Measurements on the Room Air Environment of Container Ship on the Pacific South West Route
  • ホクベイ セイガン コウロ コンテナセンナイ ニ オケル クウキ カンキョウ

この論文をさがす

説明

In the previous paper, the authors studied on the room air environment of the ferry and passenger boats operated near Japan Sea. In the present paper, the same measurements were carried out for a container ship operated between Japan and U.S. Pacific coast. It is found that the air environment for the container ship is almost within the range of the Air Quality Standards for Building Maintenance and the respirable aerosol density and CO contents are influenced by smoking. Those results correspond to the ones of the previous paper. However, the room humidity of the container ship is shown to be in a better condition than the one of the ferry and passenger boats.

収録刊行物

  • 関西造船協会誌

    関西造船協会誌 179 (0), 1-6, 1980

    公益社団法人 日本船舶海洋工学会

詳細情報 詳細情報について

問題の指摘