Relative humidities lower than about fifty percent were measured by use of saturated aqueous solutions of certain inorganic salts in the range of 10° to 50°C.<BR>In some cases, a hydrate salt existing in solid phase converts to a lower hydrate salt at a given temperature. Discontinuous changes of relative humidity were shown near this transition point.<BR>Furthermore, it was found that there was a very small difference of relative humidities between pure and impure salts. We concluded that pure salt was not necessary for humidity control only, but that cheaper impure salt was enough.