- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Development of New PCM using Sodium Acetate Trihydrate and Characteristic Evaluation of Capsule Type Heat Storage System.
-
- Kakiuchi Hiroyuki
- Tsukuba Research Center, Mitsubishi Chemical Co. Ltd.
-
- Yabe Masayoshi
- Tsukuba Research Center, Mitsubishi Chemical Co. Ltd.
-
- Yamazaki Masanori
- Tsukuba Research Center, Mitsubishi Chemical Co. Ltd.
-
- Chihara Shoichi
- Tsukuba Research Center, Mitsubishi Chemical Co. Ltd.
-
- Kubokawa Seiichi
- Ecology and Energy Division, Mitsubishi Chemical Engineering Co. Ltd.
Bibliographic Information
- Other Title
-
- 酢酸ナトリウム三水和物を用いた蓄熱材の開発およびカプセル型蓄熱システムの特性評価
- サクサン ナトリウム サンスイワブツ オ モチイタ チクネツザイ ノ カイハツ オヨビ カプセルガタ チクネツ システム ノ トクセイ ヒョウカ
Search this article
Description
We attempted to design a capsule type heat storage system, which can store heat with warm water 333 K and can produce warm water (over 320 K) directly from the heat storage tank. We developed a new PCM with melting point 323 K and heat of fusion 205 kJ/kg. This PCM was obtained by adding sodium nitrate to sodium acetate trihydrate. It is found that this PCM melted with warm water of 333 K and crystallized at 321 K. Also, it was found that heat quantity and melting point of this PCM didn't change even if freezing and melting was repeated 1,100 times.<br>We carried out characteristics evaluation of this system. It was found that this system could store heat with warm water (333 K) within 10 hours. So, this system is able to use off peak discount electric power. The theoretical heat storage quantity of this system is 322 MJ and the experimental value was 305 MJ in this evaluation. So, it is understood that this system could store heat almost equal to the theoretical value. Also, it was found that this system could produce warm water over 320 K, which is required space heating, and can release almost stored heat.
Journal
-
- KAGAKU KOGAKU RONBUNSHU
-
KAGAKU KOGAKU RONBUNSHU 27 (1), 7-14, 2001
The Society of Chemical Engineers, Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679484610304
-
- NII Article ID
- 10006553709
-
- NII Book ID
- AN00037234
-
- COI
- 1:CAS:528:DC%2BD3MXnsFyqsg%3D%3D
-
- ISSN
- 13499203
- 0386216X
- http://id.crossref.org/issn/0386216X
-
- NDL BIB ID
- 5648914
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed