書誌事項
- タイトル別名
-
- Heat Exchanger with Direct Contact of Combustion Gas and Liquid Using Packed Column
- ジュウテンソウ オ モチイタ キエキ チョクセツ セッショクシキ ネツ コウカ
この論文をさがす
説明
Submerged combustion equipment has a very high thermal efficiency, but the pressure drop is unfortunately very high within the equipment. A heat exchanger with direct contact of combustion gas and liquid using packed column has been developed in an attempt to realize a substantial improvement. It was found possible to maintain a high thermal efficiency even if the pressure drop is very low. Vaporization is likely to occur at the higher liquid temperature, so that with this new equipment operation at lower liquid temperature is effective. It became possible to use a town gas as fuel because of the low pressure drop. It was also found that the heat and mass transfer model for the packed column using the empirical equations of humidity was successful in explaining the phenomena in the high-temperature flue gas. The thermal efficiency difference between counter-current and parallel-flow operation was small within the low liquid temperature range.
収録刊行物
-
- 化学工学論文集
-
化学工学論文集 5 (6), 578-583, 1979
公益社団法人 化学工学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679487145344
-
- NII論文ID
- 130000870052
-
- NII書誌ID
- AN00037234
-
- ISSN
- 13499203
- 0386216X
-
- NDL書誌ID
- 2161480
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可