Thermal Conductivity Measurements of Liquid CO2 by the Transient Short-hot-wire Method
-
- Tomida Daisuke
- Institute of Multidisciplinary Research for Advanced Materials, Tohoku University
-
- Odashima Tsuyoshi
- Institute of Multidisciplinary Research for Advanced Materials, Tohoku University
-
- Yokoyama Chiaki
- Institute of Multidisciplinary Research for Advanced Materials, Tohoku University
Bibliographic Information
- Other Title
-
- 非定常短細線法による液体CO2の熱伝導率測定
- 化工データ 非定常短細線法による液体CO2の熱伝導率測定
- カコウ データ ヒテイジョウ タンサイセンホウ ニ ヨル エキタイ CO2 ノ ネツ デンドウリツ ソクテイ
Search this article
Abstract
Experimental results for the thermal conductivities of liquid CO2 are reported. The thermal conductivities were measured by a transient short-hot-wire method. Experimental temperatures ranged from 273.8 to 294.5 K, and pressures from 4.0 to 15.0 MPa. The uncertainty of the reported thermal conductivity data was estimated to be within ±3.0%. The experimental data were compared with calculated values from the REFPROP 8.0.
Journal
-
- KAGAKU KOGAKU RONBUNSHU
-
KAGAKU KOGAKU RONBUNSHU 36 (5), 429-431, 2010
The Society of Chemical Engineers, Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679488985728
-
- NII Article ID
- 10027619158
-
- NII Book ID
- AN00037234
-
- ISSN
- 13499203
- 0386216X
-
- NDL BIB ID
- 10946523
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed