- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
The Influence of Non-Newtonian Property on the Apparent Viscosity Measured by Single Cylinder Rotational Viscometer (Type-B Viscometer)
-
- Asai Kazuki
- Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
-
- Ichiyanagi Masaaki
- Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
-
- Satone Hiroshi
- Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
-
- Mori Takamasa
- Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
-
- Tsubaki JunIchiro
- Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
-
- Itoh Yoko
- DAITO CACAO CO.
Bibliographic Information
- Other Title
-
- 非ニュートン性が単一円筒型粘度計(B型粘度計)の測定結果に及ぼす影響について
- ヒニュートンセイ ガ タンイツ エントウケイ ネンドケイ Bガタ ネンドケイ ノ ソクテイ ケッカ ニ オヨボス エイキョウ ニ ツイテ
Search this article
Description
The measured values of apparent viscosity of non-Newtonian fluids were discussed. Alumina slurries, CMC solutions and chocolates were used as non-Newtonian fluids, and their apparent viscosities were measured by a single cylinder rotational viscometer (B-type viscometer) and coaxial cylinder rotational viscometer (coaxial viscometer). The measured values by the B-type viscometer were larger than those by the coaxial viscometer in every sample, and the flow curves measured by the coaxial viscometer were well fitted by the power law model. The ratio of the apparent viscosities measured by both viscometers was correlated with the exponent in the power law model. Instead of the exponent, a new index defined by the measurement values of the B-type viscometer was proposed in order to estimate the true values measured by the coaxial viscometer. The ratio of the apparent viscosities could be correlated with the new index as well as the exponent. It has been revealed that the true apparent viscosity can be roughly estimated by the B-type viscometer by using the new index.
Journal
-
- Journal of the Society of Powder Technology, Japan
-
Journal of the Society of Powder Technology, Japan 46 (12), 873-880, 2009
The Society of Powder Technology, Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679489596544
-
- NII Article ID
- 10026353881
-
- NII Book ID
- AN00222757
-
- COI
- 1:CAS:528:DC%2BD1MXhsF2gtL%2FJ
-
- ISSN
- 18837239
- 03866157
-
- NDL BIB ID
- 10525316
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed