Response of double layer perpendicular magnetization for shielded MR head and noise spectrum
-
- Muraoka H.
- RIEC, Tohoku University
-
- Miura K.
- RIEC, Tohoku University
-
- Sugita Y.
- RIEC, Tohoku University
-
- Nakamura Y.
- RIEC, Tohoku University
Bibliographic Information
- Other Title
-
- シールド型MRヘッドの二層膜垂直磁化応答とノイズスペクトラム
- シールドガタ MR ヘッド ノ ニソウ マク スイチョク ジカ オウトウ ト ノイズ スペクトラム
- シールドガタ MR ヘッド ノ 2ソウ マク スイチョク ジカ オウトウ ト ノイズスペクトラム
Search this article
Description
Head sensitivity function of MR heads for perpendicular double layer media was derived for the sake of the head response calculations by reciprocity theorem. Approximated Fan's function was given. Comparisons with the exact solution showed the validity of the function. Hyperboric tangent function and error function also agreed well with the Fan's solution. However, for the agreement with expermental results, assumption of an extremely narrow transition length of recorded magnetization, i.e. less than 10 nm or almost zero, was required. Further investigation would be needed for this point. Noise spectrum could also be explained by the obtained head sensitivity finctions.
Journal
-
- ITE Technical Report
-
ITE Technical Report 23.77 (0), 17-22, 1999
The Institute of Image Information and Television Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679501927296
-
- NII Article ID
- 110003226650
- 110003687479
- 10007793059
-
- NII Book ID
- AN1059086X
-
- ISSN
- 09135685
- 24241970
- 13426893
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed