Behavior of Vortex Cavitation in a Double-Suction Volute Pump
-
- SATO Toshiyuki
- (株)日立プラントテクノロジー 社会・産業システム事業本部 業務改革部
-
- TSURUTA Hiroshi
- 九州工業大学 大学院 情報工学研究科
-
- FUCHIWAKI Masaki
- 九州工業大学 情報工学研究院
-
- TANAKA Kazuhiro
- 九州工業大学 情報工学研究院
Bibliographic Information
- Other Title
-
- 両吸込み渦巻きポンプに発生する渦キャビテーションの挙動
- リョウ スイコミ ウズマキ ポンプ ニ ハッセイ スル ウズ キャビテーション ノ キョドウ
Search this article
Description
Cavitation creates three major issues which are degradation in pump, pump vibrations/noises and erosion. In order to avoid cavitation, design change and improvement of process conditions have been considered as normal design practice. Many researchers have been trying to analyse the detail of cavitation mechanism including behavior of vortex cavitation, however it has not been clarified yet. On the other hand, CFD is very useful for comprehending cavitation phenomena and CFD code has always been developed. It is well-known that there are three types of cavitation in a double-suction volute pump. These are called as vortex cavitation, reverse flow vortex cavitation and cloud cavitation. In this paper, the behaviors of vortex cavitation in the double-volute suction pump will be analyzed by using CFD.
Journal
-
- Turbomachinery
-
Turbomachinery 39 (4), 216-223, 2011
Turbomachinery Society of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679522450048
-
- NII Article ID
- 10027966372
-
- NII Book ID
- AN00004836
-
- ISSN
- 18802338
- 03858839
-
- NDL BIB ID
- 11052996
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- CiNii Articles
-
- Abstract License Flag
- Disallowed