-
- KUBO Takeshi
- Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba
-
- AKATSUKA Takao
- Division of Biomedical Engineering, Institute of Basic Medical Sciences, University of Tsukuba presently Department of Information Engineering, Faculty of Engineering, Yamagata University
-
- SHIGEMITSU Sadahiko
- Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba
-
- INABA Jun'ichi
- Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba
-
- IWASAKI Hirokazu
- Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba
Bibliographic Information
- Other Title
-
- 胎児心拍に関する各種variability indexの同一性について
- タイジ シンパク ニ カンスル カクシュ variability index
Search this article
Description
Many variability indices, which have been proposed to quantitatively represent both short-term variability (=STV) and long-term variability (=LTV), were analyzed mathematically and the following static property was obtained.<br>All of the approximate expectations for indices developed by Tarlo, Kero, Dalton, Heilbron and Cabal assumed the same formula k√1-ρσ (k: constant, ρ: correlation coefficient between the beat-to-beat interval Ti and the adjacent interval Ti+1, σ: standard deviation of Ti), and were indentical except for the constants. Those values for de Haan's and Yeh's indices were k√1-ρσ/T0 (T0: mean of Ti), while those for Modanlou's, Wade's, and Organ's indices were k√1-ρσ/T02 respectively.<br>Hence, all of these indices represented the same quantity in essence when the mean beat-to-beat interval was constant. The expected value for de Haan's and Heilbron's LTV indices was approximately k√1+ρσ (k: constant), while those for Yeh's, Organ's, and Cabal's LTV indices essentially showed standard deviation (=σ) of Ti.<br>From these results, it can be concluded that measuring STV and LTV according to those formulae means evaluating ρ and σ at the same time.<br>Hence, there may be little significance in measuring them individually if ρ changes little. That is, it may suffice merely to measure the standard deviation (=σ) of Ti as a quantity of variability.
Journal
-
- Japanese journal of medical electronics and biological engineering
-
Japanese journal of medical electronics and biological engineering 23 (1), 21-28, 1985
Japanese Society for Medical and Biological Engineering
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679533972864
-
- NII Article ID
- 130004111438
- 40000142079
-
- NII Book ID
- AN00016981
-
- ISSN
- 21855498
- 00213292
-
- NDL BIB ID
- 3037647
-
- PubMed
- 4010048
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- PubMed
- CiNii Articles
-
- Abstract License Flag
- Disallowed