Incinerator Flue Gas Cleaning Using Wet-Type Electrostatic Precipitator.

Bibliographic Information

Other Title
  • Incinerator Flue Gas Cleaning Using Wet-Type Electrostatic Precipitator(SC)

Search this article

Description

An experimental approach has been adopted to remove dioxins and other pollutants from incinerator flue gas in a pilot-scale experimental system. The main objective of this study is to investigate the combined system for simultaneous removal of gaseous pollutants and dusts. The combined gas cleaning system consists of a radiator, a scrubber and a wet-type electrostatic precipitator (ESP). Dioxins can be decomposed effectively using after-burners downstream of the incinerator by maintaining the gas temperature around 850 ± 20°C. Fractional removal rates for various kinds of dioxins (PCDDs + PCDFs) were measured in this study. When the combined system is used, dioxin removal rates of 90–92% are achieved over a wide range of initial concentrations of dioxins. The combined system is also found to be effective in the removal of NOx, SOx, HCl, and dust.

Journal

Citations (1)*help

See more

References(13)*help

See more

Details 詳細情報について

Report a problem

Back to top