EXPERIMENTAL STUDIES OF GAS VOID FRACTION AND FROTH HEIGHT ON A PERFORATED PLATE

DOI Web Site 被引用文献2件 オープンアクセス
  • TAKAHASHI TERUO
    Department of Industrial Chemistry, Okayama University
  • MIYAHARA TOSHIRO
    Department of Industrial Chemistry, Okayama University
  • SHIMIZU KENGO
    Department of Industrial Chemistry, Okayama University Nippon Synthetic Chernical Industry Co., Ltd.

書誌事項

タイトル別名
  • LOW CLEAR LIQUID HEIGHT UNDER LIQUID STAGNANT FLOW

この論文をさがす

説明

In the previous work, the vertical distribution of the gas void fraction, the froth height and the mean gas liquid fraction ratio have been clarified theoretically for low clear-liquid height on a perforated plate under liquid stagnant flow.<br> In this work, in order to make sure of these theoretical results, experimental studies were performed in the air-water system. It was found that the theoretical values of the vertical distribution of gas void fraction and froth height agreed well with experimental values. Though the theoretical value of the mean gas liquid fraction ratio agrees with the experimental values better than do those obtained by Azbel and Kim, it does not always agree with the experimental values in a wide range of Froude number. Therefore, the empirical equations for the critical Froude number and the mean gas liquid fraction ratio in each region were obtained.

収録刊行物

被引用文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ