Ion Doppler Spectroscopic Measurement with a Multi-channel PMT on Spheromak Plasmas
-
- Nagata Masayoshi
- Graduate School of Engineering, Himeji Institute of Technology
-
- Uyama Tadao
- Graduate School of Engineering, Himeji Institute of Technology
Bibliographic Information
- Other Title
-
- スフェロマックプラズマにおける多チャンネルPMTを用いたイオンドップラー分光計測
Search this article
Description
An ion Doppler spectrometer (IDS) using a compact 16 channel photomultiplier tube (PMT) has been developed and used to measure ion temperature and toroidal rotation speed on SSPX gun-spheromaks. Doppler broadening of OV spectral line shows higher ion temperature (-500 eV) as compared to the electron temperature, which indicates anomalous ion heating due to MHD relaxation. It has been also found that the plasma rotates with a speed of 60 km/s in the direction of E×B.
Journal
-
- IEEJ Transactions on Fundamentals and Materials
-
IEEJ Transactions on Fundamentals and Materials 124 (2), 217-218, 2004
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679569443712
-
- NII Article ID
- 10011965010
-
- NII Book ID
- AN10136312
-
- ISSN
- 13475533
- 03854205
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed