書誌事項
- タイトル別名
-
- Comparison of 3D Polycrtystal Magnetic Field Analysis and Distributed Magnetic Measurement
- 3ジゲン タケッショウ ジバ カイセキ ト ジッソク ケッカ ト ノ ヒカク
この論文をさがす
抄録
The three-dimensional polycrystal magnetic field analysis method is compared with the distributed magnetic measurement. In the three-dimensional polycrystal magnetic field analysis method, the local coordinates are fixed in each crystal grain and the global coordinates are defined in the polycrystal steel. It is assumed that each crystal grain has the same magnetic characteristics as those of a single crystal grain. When it is applied to the real grain oriented (GO) steel with two crystal grains and with 56 crystal grains in 80-mm × 80-mm, and with 0.35 mm thick, their results of the magnetic flux density distribution and the inclination angle are mainly explained by α angle distribution of the polyctristal steel and seem to be in good agreement.
収録刊行物
-
- 電気学会論文誌. A
-
電気学会論文誌. A 129 (11), 821-826, 2009
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679574782464
-
- NII論文ID
- 10025532737
-
- NII書誌ID
- AN10136312
-
- BIBCODE
- 2009IJTFM.129..821F
-
- ISSN
- 13475533
- 03854205
-
- NDL書誌ID
- 10481351
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可