- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Influence of Polarity-reversed Time of Applied Voltage on Surface Discharge Treatment for Gas-phase Toluene with Humidity
-
- Kadowaki Kazunori
- Graduate School of Science and Engineering, Ehime University
-
- Mori Yuji
- Graduate School of Science and Engineering, Ehime University
-
- Ozaki Ryotaro
- Graduate School of Science and Engineering, Ehime University
Bibliographic Information
- Other Title
-
- 水分を含むトルエンガスの沿面放電処理における電圧極性反転時間の影響
- スイブン オ フクム トルエンガス ノ エンメン ホウデン ショリ ニ オケル デンアツ キョクセイ ハンテン ジカン ノ エイキョウ
Search this article
Description
This paper presents an experimental study on decomposition of toluene gas in humid air using repetitive surface discharges on a dielectric barrier. Three kinds of voltages, polarity-reversed pulse with 50 ns of rise time, ac square with 0.1 ms of rise time and ac 50 Hz sinusoidal, are applied to a plasma reactor with a glass barrier between wire-plane electrode system. Experiments are done in two cases. In the first experiment, surface discharge light is observed by a still camera. Results of the photographic observation indicate that the light intensity for the polarity-reversed pulse voltage is much higher than those for the ac voltages not only under the dry condition but also under the humid conditions. It is remarked that no discharge light is observed for the ac sinusoidal voltage under the humid condition above 50 %R.H.. In the second experiment, toluene removal ratio and energy efficiency of toluene decomposition for a humid air including with 300 ppm gas-phased toluene are measured. Under a dry condition, there are no remarkable differences of the energy efficiency for toluene decomposition between the voltage waveforms. Under humid conditions, however, the energy efficiency for the ac voltages becomes lower than that for the polarity-reversed pulse voltage. The relationships between the toluene removal ratio and the consumed power can be simulated by an exponential function including geometry factor γ and discharge inception power P0. We conclude that the surface discharge treatment by the very-fast polarity-reversed pulse is an effective way for toluene decomposition under humid conditions.
Journal
-
- IEEJ Transactions on Fundamentals and Materials
-
IEEJ Transactions on Fundamentals and Materials 135 (8), 473-480, 2015
The Institute of Electrical Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679575272064
-
- NII Article ID
- 130005090596
-
- NII Book ID
- AN10136312
-
- ISSN
- 13475533
- 03854205
-
- NDL BIB ID
- 026672363
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed