塔槽類に生じる地震モーメントの簡易算定方法

書誌事項

タイトル別名
  • The Simplified Evaluation Method of the Seismic Moment for Towers and Tanks
  • トウソウルイ ニ ショウジル ジシン モーメント ノ カンイ サンテイ ホウホウ

この論文をさがす

説明

There are some cases in which towers and piping with insulation have become externally corroded after long usage. The FFS (Fitness for Service) code based on the p-M method proposed by Konosu et al. can be used to assess the structural integrity of towers and piping with local thin areas simultaneously subjected to internal pressure and external bending moment. <br> However, in order to assess structural integrity by the p-M method, it is necessary to evaluate the bending moment due to earthquake, etc. , at the location with the local thin area concerned. <br> There is an earthquake resistant design code published by the High Pressure Gas Safety Institute of Japan (KHK) in which details relating to seismic loads are given. <br> In this paper, the seismic moment for various towers is calculated as per (1) static coefficient method, (2) modified static coefficient method and (3) modal analysis method etc. By comparing these results, the simplified equation based on the static coefficient method and the modified static coefficient method is proposed.

収録刊行物

  • 圧力技術

    圧力技術 45 (1), 28-38, 2007

    一般社団法人 日本高圧力技術協会

被引用文献 (1)*注記

もっと見る

参考文献 (5)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ