Comparison of Buckling of Aboveground Oil Storage Tanks and Cylindrical Shells under both Internal and External Liquid Pressure

Bibliographic Information

Other Title
  • 内部液体と外部液体から静液圧を受ける石油タンクと円筒シェルの座屈比較
  • ナイブ エキタイ ト ガイブ エキタイ カラ セイ エキアツ オ ウケル セキユ タンク ト エントウ シェル ノ ザクツヒカク

Search this article

Description

Powerful tsunami attacked to the northeast coast of Japan due to the Great East Japan Earthquake occurred on March 11, 2011. Some aboveground storage tanks (ASTs) were subjected to external pressure due to the tsunami. This paper presents the bifurcation buckling of shell plates in 1, 000m3 , 10, 000m3 and 90, 000m3 AST under both internal and external liquid pressure using the axisymmetric shell finite element method. The buckling of cylindrical shells which have the same diameter and thickness as ASTs has been also analyzed for the comparison. The buckling liquid height of an AST is less than that of a cylindrical shell. The reduction ratio of buckling liquid height of an AST from a cylindrical shell is proposed. The buckling liquid height of an AST can be simply obtained from that of a cylindrical shell using the reduction ratio.