A Compact Excimer Lamp Constructed by Piezoelectric Transformer
-
- TERANISHI Kenji
- Research Fellow of the Japan Society for the Promotion of Science (Chiba Institute of Technology)
-
- ITOH Haruo
- Graduate School of Engineering, Chiba Institute of Technology
この論文をさがす
説明
A compact excimer lamp constructed with a piezoelectric transformer (PT) has been developed in our laboratory. This excimer lamp is designed based on the excitation of a dielectric barrier discharge (DBD) in a He-Xe mixture generated by the PT, which is driven with low applied voltages of several tens of volts (15-45V). Vacuum ultraviolet (VUV) radiated from the lamp is detected by a phototube having a spectral response region ranging from 160 to 320 nm in conjunction with an optical filter to discriminate the VUV and UV regions. The VUV radiation in the wavelength range 160-200 nm is recognized in this experiment. This may be derived from the 172-nm light emission by the transitions of the Xe2 excimers to the ground state. Investigations into the radiated VUV intensity are carried out by varying the gas pressure and the gap length. The optimal condition for the present excimer lamp is determined.
収録刊行物
-
- Journal of Light & Visual Environment
-
Journal of Light & Visual Environment 31 (1), 5-10, 2007
一般社団法人 照明学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679594148352
-
- NII論文ID
- 110006241754
-
- NII書誌ID
- AA00258424
-
- ISSN
- 13498398
- 03878805
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- NDL-Digital
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可